UV wood and panel matting covers 5 synthetic amorphous silica grades (CAS 7631-86-9) for UV-cured wood and panel coatings applied by roller or spray. Particle size D50 across the range runs 3.8–8.5 µm, with BET surface area 90–165 m²/g and oil absorption 135–205 g/100 g. SiO₂ content is 96–97.2 %. Grades in this range: VS3550U, VS370U, VS6907, VS141S, VS641. Typical dosage is set by screening in your own system — set the grade first from clarity and texture constraints, then find the loading that meets your gloss target.

Where it applies

  • UV roller-coated panel, door and flooring
  • UV spray furniture topcoats
  • Panel processing lines

What the solution is built around

Separate screening paths for roller and spray UV lines, because one grade does not generalise across both processes. The screening logic starts from the coating system rather than from a single matting figure — resin type, target gloss, application method and the specific problem you are seeing all change which grade should lead.

Low gloss. More uniform panels.

Recommended grade structure

Each project starts with a lead grade and at least one comparison grade. Running both against your own control in the first round answers more than running one grade twice.

Grades for uv wood & panel systems
Grade Role Particle size (µm) Application note
VS3550U Lead (roller) 5.5–6.0 High surface area route; first screen for roller application.
VS370U Support (roller) 7.0–7.3 Compare matting depth against surface uniformity.
VS6907 Reserve (roller) 8.0–8.5 Held for lower gloss targets.
VS141S Lead (spray) 3.8–4.0 Fine route for spray appearance and surface refinement.
VS641 Support (spray) 3.8–4.2 Comparison sample within spray systems.
UV coating comparison — uneven gloss vs uniform matte finish
Before — Uneven gloss After — Uniform matte

What to measure in the first round

These are the dimensions that decide whether a grade progresses. Test against your own control sample under production-representative conditions wherever possible.

Verification checklist
Dimension What good looks like
Gloss & uniformity Stable low gloss; no mottling across the panel
Process fit Roller transfer, spray atomisation and flow behave normally
System viscosity Addition does not close the process window
Cured appearance No seeding, cratering or gloss drift

Technical support on this solution

  • System review — resin type, target gloss, application method, current issue and incumbent product.
  • Two-sample proposal — a lead grade plus a comparison route, with the reasoning for each.
  • Lab and scale-up — comparison across appearance, process behaviour and storage stability.
  • Troubleshooting — support on haze, drag, thickening, settling and appearance defects.
Before you order samples

Tell us the resin system, the gloss target and standard you measure against, the application method and film build, and what is going wrong today. That turns a sample request into a screening plan with a defined answer.

Screening starts with the system

Resin, target gloss, application method, current problem. We reply with a plan.

Talk to an application specialist
Common questions

Selecting and screening for this system

Which grade should lead a first screening round for UV wood and panel coatings?

VS3550U is the usual starting point for UV wood and panel coatings, at a recommended dosage of 1-3 % on total formulation. Run at least one comparison grade in the same round rather than running VS3550U twice — VS370U, VS6907, VS141S, VS641 cover the rest of the working range for this system. Testing two grades against your own control in round one answers more than testing one grade in two rounds.

How do the grades in this range differ?

Particle size across this range runs VS141S at 3.8-4.0 µm; VS641 at 3.8-4.2 µm; VS3550U at 5.5-6.0 µm; VS370U at 7.0-7.3 µm; VS6907 at 8.0-8.5 µm. The finer end (VS141S) scatters less light inside the film and generally preserves more clarity; the coarser end (VS6907) creates more surface texture per unit added and reaches a lower gloss at lower loading. Structure differs too: VS141S carries the highest surface area in this group at 165 m²/g against 90 m²/g for VS6907, which means it thickens the formulation more at the same loading.

What dosage should I start with?

For UV wood and panel coatings, VS3550U typically starts at 1-3 % on total formulation. Treat this as a bracket rather than a target: screen three loadings around it and interpolate to your gloss reading. Set the grade first based on clarity and texture constraints, then find the loading that hits gloss — starting from a fixed loading and searching for a grade usually produces something that meets gloss and fails elsewhere.

My gloss is right but the finish has another problem. What do I change?

For UV wood and panel coatings, the common issue is surface uniformity through cure at line speed. Gloss is the easy variable — it is corrected by adjusting loading. What loading cannot correct is clarity, surface texture and dispersion stability, and those are set by the grade. If the current grade meets gloss but fails on one of those, move along the particle size range rather than changing the loading: finer toward VS141S for clarity, coarser toward VS6907 for matting efficiency at lower loading.

How should I compare a Vistamatt grade against my current control?

Compare at matched gloss, not at matched loading. Different grades have different matting efficiency, so running a candidate at the incumbent's loading gives a different gloss reading — that tells you about efficiency, which is easily corrected, and nothing about the properties that are not. Find the loading that matches your gloss target first, then compare clarity over your darkest substrate, surface texture by hand, and wet formulation viscosity at that loading.

What do I get with a sample request, and what are the commercial terms?

Samples are free, 200–500 g, with freight prepaid by Vistamatt, and ship in 7–10 working days with a screening plan matched to your system. MOQ is 500 kg per grade for standard grades and 2,000 kg for a custom batch; production lead time is 15–25 days, FOB Xiamen or CIF. Documentation includes a TDS per grade, a generic SDS covering the range, a TSCA compliance declaration, and a COA per batch on request.

Grade recommendations are a starting point for screening. Final suitability, dosage and performance must be verified in the customer's own resin system, at the target gloss and under actual process conditions.